Is Your Facility Protected By Using The Latest Technology?

5. December 2011 14:25 by Jeff Duret in   //  Tags:   //   Comments (0)

Ultrasonic - A vital part of your EDS preventive maintenance program

You likely have heard of using Infrared Technology as part of your Preventive Maintenance Program, but does this catch all of the potential problems / deficiencies?

The answer is simply - NO!

Ultrasonic is a very important part of the TEGG Preventive Maintenance Solution. The two technologies used together, compliment one another and offer the most reliable method of protection from unplanned power outages and failure.

A few of the issues that Ultrasonic will identify that may otherwise be overlooked are Corona, Tracking, Low-Level Arcing, and Contact chatter.

Whether you have a solid preventive maintenance program in place and would like to see if there is room for improvement or are seeking help with developing a new program, call today for a free consultation with one of our certified TEGG specialists. Let us help you reach your goals.

Master Electric
952-890-3555

     
     
     
     
     
     
     
     

Importance of Testing and Exercising Branch Circuit Breakers

26. October 2011 14:17 by Jeff Duret in   //  Tags:   //   Comments (0)

Testing and Exercising Branch Circuit Breakers

This report is from a Data Center Manager and discusses the importance of proper maintenance of your circuit breakers.

 

"Any significant down time at my data centers could potentially cost the company millions of dollars in lost revenue, so I looked for every possible problem area and implemented preventative maintenance measures to ensure that downtimes were either minimized or eliminated. One preventative maintenance measure was to pre-test all branch circuit breakers prior to installation. 

 

The last line of defense protecting your critical servers on the raised floor are the branch circuit breakers located within your PDU/RPP's. Considering how many breakers are produced each day, regardless of the brand name, some may have defects. This can lead to several problems. If the branch circuit breaker does not trip on a direct short, the next breaker in line will be the main breaker in your 42 circuit panel and can lead to widespread failures of your critical servers on the raised floor. In the event of an overloaded circuit, if the individual branch breaker does not trip, over time, it can cause a fire.

 

I found from my years of experience of testing branch circuit breakers installed in our data centers, between overloaded branch circuits and direct shorts, about a 4% failure rate. Even though 4% may not seem like a large percentage, in most data centers, 4% of the thousands of circuit breakers used can still place a significant number of servers at risk".

 

"Another very important maintenance practice is to exercise the breakers at least every two to three years. This should not be overlooked when implementing scheduled maintenance shutdowns.

 

My recommendation is that each branch circuit breaker is exercised by turning them off and on at least three to four times. This will ensure the breaker does not become seized in the closed position which could prohibit them from tripping in the event of a direct short or overloaded circuit.

 

If it is continuous uptime you are seeking to achieve, along with a good maintenance program, testing and exercising branch circuit breakers is a proactive maintenance measure well worth implementing".

Master Electric's TEGG services can provide additional solutions that will help identify signs of premature and imminent electrical failures similar to what is described above.

TEGG Service could have detected and prevented this Electrical Fire before it caused a $750,000 loss

6. October 2011 12:18 by Jeff Duret in   //  Tags:   //   Comments (0)

About 9,000 turkeys killed in barn fire near Pelican Rapids

Pelican Rapids, Minn. (WDAY TV) - Fire officials say electrical issues might be to blame for a barn fire near Pelican Rapids that killed about 9-thousand turkeys.

 Firefighters worked to contain the Tuesday night blaze, but the building and its 9 thousand turkeys were a total loss. The turkeys were set to go to market next week.

 Losses are estimated at up to 750-thousand dollars. The barn was located about 4 miles east of Pelican Rapids and is owned by Gorton Turkey Farms.

Protect your business and employees from catastrophic electrical events such as this. Contact Master Electric today for a free consultation.

Destroyed Turkey barn

 